    I don't think you fully understand the issue I was having. The Rem terminal on the amplifier that is supposed to GET 12v to turn the amp ON, is showing 9v coming FROM the remote turn on terminal and amplifier is showing powered on with only 12v and ground connected to amplifier. There is nothing...
  2. Y

    Remote turn on lead work around options...

    UPDATE: I ran a parasitic draw test on the amp in question. When the light indicates it is on, but with only the primary ground and power wires connected, draw is approx. 0.7A or 700mA, which is too high to leave unattended of course. I tried to draw the power measured from the REM line to...
  3. Y

    Remote turn on lead work around options...

    I have a 11DX 400.4 kicker amplifier. It works as an amplifier, however without knowing what happened, I now do not have the ability to turn off the amp via the remote wire...(based on the green power, not orange power protect light)... When I disconnect all wires from the amp except primary...